The 7600REF reference and test signal generator is a high-stability standalone 1 RU unit for providing system timing. It has a complete set of reference signals, including a master Genlock reference loop-through input. It can be used in either master or slave roles. A powerful feature is timecode generation, as well as a complete set of reference signals, allowing for a very compact timing solution. Reliability is a top feature of the 7600REF with dual-redundant power supplies and the ability to interface to the 7620PX changeover unit for backup.
For versatility, the 7600REF has no less than five individually timed analog black and burst reference outputs. In addition, three SDI feeds provide individual test signals, including full-field signals where each can be separately configured. A full set of audio test signals are provided with analog audio available as well as unbalanced AES and embedded audio outputs.
The 7600HD option provides for an additional four Tri-level sync outputs and a full set of HD test signals.
The timecode generator options allow for a versatile solution to timecode. Longitudinal and vertical interval timecode LTC and VITC can be output.
The 7600REF can act as an NTP server ensuring IT-based units keep in step with the broadcast infrastructure. The time generated can be set from GPS satellites through the 7600GPS option. This makes the 7600REF an ideal unit for OB operation.

Inputs
Genlock: One input (with loop-through)
5/10 MHz reference: One input
Outputs
Analog video: Five standard outputs 625/525 (black burst and test)
HD/SD SDI: Three (HD/SD test) SD standard, HD optional
AES: Two balanced (AES 2003-11) 32/44.1/48.96 kHz, two unbalanced with 7600MHD-REF version
Analog audio: Two channels
27 MHz/10 MHz/word clock: OnE standard
LTC/VITC: Two (optional)
GPS Receiver (7600MHD-REF)
Performance
Accuracy: <±0.5 Hz (0.1 ppm)
Temperature stability: < 0.1 ppm
Aging: <3 Hz per year
Genlock offset: ±4 fields in 1 ns step
Genlock phase: 0-350° in 0.1° steps
Black burst and test signal: ±4 fields in clock steps
SDI back and test signal: ±2 fields in clock steps
Tone frequency: 100 Hz to 10 kHz in 100 Hz steps
Tone amplitude: 0 dB to -40 dB in 1 dB steps (L&R)
Control and Monitoring
Front panel display with configuration menu access GPI:
Network interface: TFTP download
Slave configuration retrieval from master
Power
90 to 260 VAC, 47 to 63 Hz, 75 VA
Weight
Max. 5.2 kg fully equipped
Dimensions
Height: 44 mm (1 RU)
Width: 483 mm
Depth (excluding connectors): 400 mm
Environmental
Operating temperature: +0° to +50°C
GeckoFlex 7600REF Reference and Test Signal Generator Data Sheet
|
|||
![]() |
|||