The 8912RDA brings balanced digital audio distribution to the 8900 family of products. This module complements the 8911 AES reclocking DA by offering terminal-screw connectors for those facilities requiring balanced I/O. With built-in impedance conversion, you can select either 75Ω or 110Ω inputs. In addition, we've added a powerful remote monitoring capability to enable you to keep track of all your conversion and distribution assets using our NetCentral® SNMP-based remote monitoring software.

Supported Frame Types
GeckoFlex with 8900A-R GeckoFlex Audio rear module, Gecko audio frames: 8900TX-A, 8900TF-A, 8900TFN-A
Power Rating
4 Watts – single slot
Input
Signal type: AES-3id-1992 or AES3 transformer coupled
Number of inputs: One
Impedance: 75Ω, 110Ω, or High Z
Connectors: BNC or terminal block
Sample rate: 32 kHz to 96 kHz
Input return loss: (100 kHz to 10 MHz) >15 dB balanced, >25 dB unbalanced
Balanced input common mode voltage range: ±10V 50 Hz to 20 kHz
Output
Signal type: AES3 AC coupled
Number of outputs: Eight
Impedance: 110Ω
Connectors: Terminal block
Sample rate: 32 to 96 kHz
Output return loss: >15 dB (100 kHz, 10 MHz)
Performance
Reclocking: Yes
DC offset: <±1 mV
Ability to lock jitter: .2 UI
Intrinsic jitter: 0.025 UI
Electrical length: 135 µs @ 48 kHz (or ~6.5X sample rate period)
Other
User controls: Input impedance
Operating temperature: 0° to 45°C
Humidity range: 0% to 90% non-condensing
Non-operating temperature: –10° to 70°C
Remote – SNMP alarm
GeckoFlex 8912RDA AES/EBU Reclocking Distribution Amplifier Data Sheet
|
|||
![]() |
|||