The 8972PX is a full-time signal protection switch. It is a highly robust primary/secondary changeover switch for HD-SDI, SD-SDI, or ASI signals. It can be controlled by autonomous switching to a backup signal using in-built detection of signal failure, switched by manual controls, or driven by an external GPI system to switch on command.
The 8972PX fulfils the basic requirement of any protection system by not adding failure modes to the existing signal path. In the event of a power failure, or even if the front control module is completely removed, the Program Output signal will continue to pass from the previously selected input as a fail-safe relay path will latch the selected signal to the output. In driven mode it can be configured by GPI or Ethernet.
All parameters can be configured via the web browser interface and main parameters via the Newton™ Control Panel. NetConfig™ and NetCentral® are supported respectively for remote configuration and product health monitoring. Asserting GPI control or other manual controls will disable autonomous control.

Supported Frame Types
GeckoFlex with 8900NET (Net Card) for configuration
Power Rating
9.0 Watts – dual slot
Inputs
HD/SD-SDI or ASI: Three
Outputs
Protected outputs: One
Insertion loss on protected output when bypassed: Equivalent to less than 20m of Belden 1694A cable
Return loss: <15 dB (when signal is not bypassed)
Distributed outputs: Seven
Return loss: <15 db
GPI
GPO
Primary input status (failed/good)
Secondary input status (failed/good)
Alternate input status (failed/good)
Switch state (primary/secondary/alternate)
Control and Monitoring
SNMP: Monitoring and switching control
Web page configuration: Yes
Local configuration: Switching control only
Newton™ support: Yes
NetConfig™ support: Monitoring only
GeckoFlex 8972PX Protection Switch Data Sheet
|
|||
![]() |
|||