IQH3B enclosures offer industry-leading, high-density delivery of modular solutions. The 3 RU enclosure accepts up to 16 modules, and has dual redundant PSUs and cooling fans. Analog reference signals can be distributed through the enclosures via two connections that can be independently selected by the installed modules. Control and monitoring is included as standard using the latest generation Gateway (IQRCG) control card that has its own module style rear connector, providing improved (faster) control template access, HTML5 web browser connectivity, dual Ethernet support with DHCP and improved menu caching, with full GV Orbit and SNMP control and monitoring functionality.

FEATURES
- 16 single or 8 double-width modules (or any combination)
- Plug-in gateway communications card to enable RollNet, and GV Orbit control over TCP/IP Dual 1 GbE connections
- Fast control access with full menu and control caching for all modules
- Integrated HTML5-based web browser access for enclosure and module configuration and control
- SNMP Control and Monitoring of all inteligent IQ modules as standard
- Dual Ethernet with DHCP support, failover rules and auto-discovery
- Dual redundant network architecture over Ethernet and RollNet enables mission-critical control applications to function even if a complete network failure occurs
- 2x analog reference signal distribution for dual standard (bi-level or tri-level), dual video standard (SD or HD), and reference redundancy applications with reference status reporting (Note: Only applicable to modules with -B order codes)
- Hot-swappable redundant power supplies
- Optimum use of rack space — frames do not require any additional ventilation spacing
- Dual redundant in-service removable fan unit
- Variable fan speed, dependent upon load and ambient temperature
- Full chassis monitoring, including inlet and outlet temperature, fan condition and module status
- Door status monitoring (open/close)
- Full CE and UL compliance
SPECIFICATIONS
Inputs, Outputs and Controls
Inputs/Outputs
RollNet remote control:
- BNC connector
GV Orbit/SNMP over TCP/IP
10/100/1000baseT dual Ethernet
Controls via GV Orbit Remote Control System
Full control via HTML5 interface (available from chassis), any hardware RollPod control surface and GV Orbit
General Specifications
Module complement: 8 double width or 16 single width (or combinations of both) fitted vertically
Module card dimensions: 100 mm wide, 340 mm long (3.9 in. wide, 13.4 in. long)
Module rear panel dimensions:
- Height: 129 mm (5.0 in)
- Double width: 40.4 mm (1.6 in.)
- Single width: 20 mm (0.8 in.)
Power
Input voltage range: 100-240 V 50/60 Hz
Input connector: IEC320 Fused 4 A(T)
Standby switch: Behind drop-down front panel
Power consumption: 300 VA maximum
Modules power dissipation: 210W/165 LU maximum (100 LU for IQH3BQ)
Output: +7.5V and -7.5V ±5%
Note that all modules have built-in power supply fuses.
CE Performance Information
Environment: Commercial and light industrial E2 immunity, controlled EMC E4 emissions
Peak mains inrush current following a 5 second mains interruption: 10A
Reference
Analog reference:
- 2x analog reference inputs
- Black (HD tri-level and SD bi-level) and black burst (SD bi-level)
- SD bi-level – RS-170A
- HD Tri-level – SMPTE ST 240, SMPTE ST 274 and SMPTE ST 296
Connector/Format: BNC/75Ω panel jack on standard IQ connector panel
Analog reference return loss:
- SD bi-level > 40 dB to 5.5 MHz
- HD tri-level > 35 dB to 30 MHz
Mechanical
Temperature range: 0 to 45° C (32° to 113° F) operating, -20 to +85° C (-4 to 185° F) storage. A temperature- and load- sensitive cooling fan is fitted
Humidity range: 10 to 85% (non condensing)
Case type: 3 RU rack mounting aluminum case
Dimensions:
- Width: 483 mm (19.0 in.) (445 mm 17.5 in.) behind rack location bracket
- Depth: 490 mm (19.3 in.)
- Height: 135 mm (5.3 in.)
Weight:
- Approximately 8.25 kg (18.2 lbs.) without modules
- Approximately 15 kg (33.1 lbs.) fully populated
Please refer to the IQH3B and respective IQ module Operators Manuals to determine the module power rating limits (PR) for your required configuration. In the IQH3B Enclosure power is quoted in Load Units (LU), which refers to power (in Watts) taken from the positive rail. The IQH3B has 165 Power loading (LU) units available for modules. The Power Ratings of each module should be added together and the total should not exceed 165 loading units. Modules that do not specify a “Power Rating” should use the total power figure (W) as a power rating value.
MEDIA GALLERY




ORDERING INFORMATION
IQH3B-S-P
Enclosure with Dual Redundant PSU and Ethernet/SNMP Compatible GV Orbit Gateway Card. 16 module slots
IQH3B-SQP
100 load unit quiet enclosure with Dual Redundant PSU and Ethernet/SNMP Compatible GV Orbit Gateway Card. 16 module slots
Accessories
IQH3B-PSU
Single PSU as cold spare or upgrade to dual PSU configuration
IQH3B-FAN
Dual Fan unit for use as cold spare or replacement
IQRCG0000-1B
Ethernet/SNMP compatible GV Orbit Gateway card for IQH4B and IQH3B enclosures
Notes: Although IQ modules are interchangeable between enclosures, each enclosure requires a suitable variant of panels:
- Either ‘A’ or ‘B’ order codes may be used when installing modules in IQH3B enclosures
- ‘A’ build rear panels will fit into IQH3B enclosure, however features such as frame reference (if relevant to the module) would not be supported by those modules